The versatile Sinamics S210 servo inverter is mainly designed for dynamic, discontinuous applications.
For very high requirements, where the integrated braking resistor is not sufficient, an intrinsically safe braking resistor with temperature monitoring from Koch is used. For this purpose, an assignment of suitable brake resistors for the different power classes was defined in close cooperation with Siemens. Matching the S210 in the compact design by Koch, which meets the high requirements of the overall system. A safe operation of dynamic applications is thus guaranteed.
Spotlight
Allocation - Brake resistors for SINAMICS S210
Allocation - Brake resistors for SINAMICS S210





Contact
Rated power |
Allocation - Brake resistors for SINAMICS S210 |
Resistance |
Allocation - Brake resistors for SINAMICS S210 |
Tolerance (resistance) | +/- 5 [%] (Room temperature) |
Converter | Brake resistor, Michael Koch GmbH | ||||||
SINAMICS Products | Rated Power in [kW] | Koch number with Temperature sensor 190°C | Continuous Power in [W] for CE | Continuous Power in [W] for UL | Max. Peak Performance in [W] | Max. Brake Energy in [kJ] | |
Mains voltage 1 AC 200 ... 240 V | |||||||
6SL3210-5HB10-1UF0 | 0,1 | BWG250047TS-190 | 50 | 50 | 350 | 0,7 | |
6SL3210-5HB10-2UF0 | 0,2 | BWG250047TS-190 | 100 | 100 | 600 | 1,1 | |
6SL3210-5HB10-4UF0 | 0,4 | BWG250047TS-190 | 100 | 100 | 1300 | 1,8 | |
6SL3210-5HB10-8UF0 | 0,75 | BWG500027TS-190 | 200 | 200 | 2400 | 2,7 | |
Mains voltage 3 AC 200 ... 240 V | |||||||
6SL3210-5HE10-4UF0 | 0,4 | BWG500027TS-190 | 200 | 200 | 600 | 0,9 | |
6SL3210-5HE10-8UF0 | 0,75 | BWG600014TS-190 | 380 | 240 | 1200 | 0,8 | |
6SL3210-5HE11-0UF0 | 1,0 | BWG600014TS-190 | 400 | 240 | 1700 | 0,8 | |
6SL3210-5HE11-5UF0 | 1,5 | BWD500027K03LIP65IS | 600 | 600 | 2900 | 14,5 | |
6SL3210-5HE12-0UF0 | 2,0 | BWD500027K03LIP65IS | 600 | 600 | 3800 | 13,9 | |
6SL3210-5HE13-5UF0 | 3,5 | BWD600014K03LIP65IS | 1200 | 720 | 7500 | 18,7 | |
6SL3210-5HE15-0UF0 | 5,0 | BWD600014K03LIP65IS | 1200 | 720 | 9500 | 17,8 | |
6SL3210-5HE17-0UF0 | 7,0 | BWD600014K03LIP65IS | 1200 | 720 | 12500 | 18,2 | |
Mains voltage 3 AC 380 ... 480 V | |||||||
6SL3210-5HE10-4UF0 | 0,4 | BWG500100TS-190 | 200 | 200 | 1200 | 5,2 | |
6SL3210-5HE10-8UF0 | 0,75 | BWG600047TS-190 | 380 | 240 | 2400 | 6,2 | |
6SL3210-5HE11-0UF0 | 1,0 | BWG600047TS-190 | 400 | 240 | 3400 | 6,1 | |
6SL3210-5HE11-5UF0 | 1,5 | BWD500100K03LIP65IS | 600 | 600 | 5700 | 30,4 | |
6SL3210-5HE12-0UF0 | 2,0 | BWD500100K03LIP65IS | 600 | 600 | 7600 | 30,4 | |
6SL3210-5HE13-5UF0 | 3,5 | BWD600047K03LIP65IS | 1200 | 720 | 15000 | 50,0 | |
6SL3210-5HE15-0UF0 | 5,0 | BWD600047K03LIP65IS | 1200 | 720 | 19000 | 47,5 | |
6SL3210-5HE17-0UF0 | 7,0 | BWD600047K03LIP65IS | 1200 | 720 | 25000 | 41,7 |
- compact
- highly impulse secure
- space saving
- low inductance
- protection class up to IP 65
- intrinsically safe* under persistent overloads
- no short-circuit
- self-extinguishing
- no fault to frame
* The intrinsically safety is usually given with 4 time of permanent type power.