Brake resistors to SINAMICS G110M
Siemens Product Partner
SINAMICS G110M - Brake resistors

The decentral inverter with a high protection class (up to IP66) is built in a modular way, consists of a control unit and power module, and is designed for use as a motor-integrated inverter on SIMOGEAR gearmotor. A safe brake resistor that meets comparable requirements is best suited for these special demands. KOCH has also created a fitting solution here. Whether the inverter is equipped with an option such as a maintenance switch or a 24V power supply, or it is used without such an option, the external brake resistors can be connected easily and without hassle.

Spotlight

CE Logo
RoHS Logo
CSA Logo
REACH Logo
UL Recognized Component Logo

Contact

Michael Koch GmbH
Phone: +49 7251 96 26-200
Fax: +49 7251 96 26-210
Technical specifications
Dimensions
Allocation – Braking resistors to G110M
Advantages
Downloads
Rated power 240 [W] (600 with duty cycle ED = 35%, ϑA = 20°C)
Resistance 80 [Ω] 200 [Ω]
Tolerance (resistance) ± 5 [%] (Room temperature)
Maximum permissible operating voltage (Taking into consideration the "intrinsic safety") 700 AC [V] 1.000 DC [V]
Maximum permissible operating voltage (Taking into consideration according to cCSAus and UL) 600 AC [V] 848 DC [V]
Inductance 30 (f = 300 kHz, Umess = 50 mV)

Dimensions and mounting holes (mm)
Example of version with shielded cable

  • Dimensions
    Dimensions
  • Dimensions
    Dimensions
  • Stainless steel cover perforated
    Stainless steel cover perforated

Version with protection tube

SINAMICS Produkte KOCH number Execution max. Power kW 5% duty-cycle*** Ohm value nominal Power [W]
FSA BWD600200K01SI-1 Without locking plate 4 200 240
FSB BWD600080K01SI-1 Without locking plate 4 80 240
FSA BWD600200K01SI-2 With locking plate 4 200 240
FSB BWD600080K01SI-2 With locking plate 4 80 240

Version with shielded cable

SINAMICS Produkte KOCH number Execution max. Power kW 5% duty-cycle*** Ohm value nominal Power [W]
FSA BWG600200K01SI-3 Without locking plate 4 200 240
FSB BWG600080K01SI-3 Without locking plate 4 80 240
FSA BWG600200K01SI-4 With locking plate 4 200 240
FSB BWG600080K01SI-4 With locking plate 4 80 240

***at an ambient temperature of 20° C

  • compact
  • space saving
  • protection class up to IP 65*
  • highly impulse secure
  • low inductance
  • "intrinsically safe"** under persistent overloads
    • no short-curcuit
    • no fault to frame
    • self-extinguishing

*Test conditions: Water jet from nozzle with an inner diameter of 6.3mm, volume flow 12.5l/min +/- 5%, water pressure in accordance with the volume flow, distance 2.5-3m, test duration 3min

**the intrinsically safety is usually given with 4 time of permanent type power