With the SINAMICS S200 servo drive system, the focus is on higher productivity and improved efficiency at lower costs. The servo inverter is Performance-optimized, Easy to use and Fit for future. In cooperation with SIEMENS, we as a product partner have also assigned our intrinsically safe brake resistors. The appropriate brake resistor can be easily selected using the assignment table.
Rated power
ALLOCATION – BRAKE RESISTORS FOR SINAMICS S200
Resistance
ALLOCATION – BRAKE RESISTORS FOR SINAMICS S200
Contact
Michael Koch GmbH
Phone: +49 7251 96 26-200
Mail: mail@bremsenergie.de
ALLOCATION – BRAKE RESISTORS FOR SINAMICS S200
Advantages
Technical specifications
DIMENSIONS
DOWNLOADS
ALLOCATION – BRAKE RESISTORS FOR SINAMICS S200
Voltage | Frame size | Resistance | max. peak power [W] | continuous power [W] |
max. energie [J] | KOCH Brake Resistor number | Resistance | Maximum peak power (5% ED**) (W)* |
Maximum continuous power [W] |
1 AC/3 AC, 200 V … 240 V |
FSA (0.2 kW) | 200 | 373 | 8 | 63 | BWD250200 | 200 | 1500 | 100 |
1 AC/3 AC, 200 V … 240 V |
FSB (0.4 kW) | 100 | 742 | 16 | 123 | BWD250100 | 100 | 1500 | 100 |
1 AC/3 AC, 200 V … 240 V |
FSC (0.75 kW, 1 kW) | 50 | 1884 | 30 | 292 | BWD500050 | 50 | 2750 | 200 |
3 AC, 380 V … 480 V |
FSA (0.2 kW, 0.4 kW) | 500 | 754 | 14 | 210 | BWD250620 | 620 | 1500 | 100 |
3 AC, 380 V … 480 V |
FSB (0.75 kW … 1.0 kW) | 160 | 2312 | 15 | 637 | BWD500160 | 160 | 2750 | 200 |
3 AC, 380 V … 480 V |
FSC (1.75 kW … 2.5 kW) | 70 | 5086 | 30 | 1137 | BWD600072 | 72 | 4000 | 240 |
3 AC, 380 V … 480 V |
FSD (3.5 kW … 7.0 kW) | 27 | 9896 | 65 | 1948 | BWD600100K03LV | 33,3 | 12000 | 720 |
* at an ambient temperature of 20°C
** in a 240s-Cycle
Advantages
*Test conditions: Water jet from nozzle 6.3 mm inside diameter,
flow rate 12.5 l / min +/- 5%, water pressure according to volume flow,
distance 2.5- 3m, test duration 3min.
**With fourfold type power and free convection. 1. no short-circuit, 2. no fault to frame, 3. self-extinguishing, 4. no melting of casing. Type power always corresponds to 35% duty cycle of the respective resistor type.
Technical specifications
Parameter | Symbol | Value | Unit | Conditions |
---|---|---|---|---|
Tolerance (resistance) | ± 5 | % | Room temperature | |
Temperature coefficient | TK | 20 … 100 | 10-6/K | |
Insulation resistance | Riso | ≥ 100 | MΩ | Umess = 1,000 VDC |
Inductance | L | ≤ 30 | µH | f = 300 kHz, Umess = 50 mV |
Capacity against enclosure | C | ≤ 300 | pF | f = 300 kHz, Umess = 50 mV |
Certifications | cCSAus | Standard CSA-C22.2 and UL508 | ||
cCRus | Standard CSA-C22.2 and UL508 | |||
Maximum permissible operating voltage | UB | ≤ 700 AC | V | Taking into consideration the „intrinsic safety“ |
UB | ≤ 1,000 DC | V | Taking into consideration the „intrinsic safety“ | |
Maximum permissible operating voltage | UB | ≤ 600 AC | V | according to CSA |
UB | ≤ 848 DC | V | according to CSA | |
Isolation voltage | Uiso | ≥ 4,000 AC | V | f = 50 Hz; t = 1 s |
Max. permissible case temp. | ϑc | ≤ 250 | °C | unobstructed convection |
Storage temperature | ϑs | -25 … +85 | °C |
DIMENSIONS
Dimension table | |||
Brake resistor number | H (mm) | B (mm) | T (mm) |
BWD250200 | 110 | 80 | 15 |
BWD250100 | 110 | 80 | 15 |
BWD500050 | 216 | 80 | 15 |
BWD250620 | 110 | 80 | 15 |
BWD500160 | 216 | 80 | 15 |
BWD600072 | 216 | 80 | 30 |
BWD600100K03LV | 216 | 223 | 91,5 |
We will gladly send you dimensional drawings on request.
DOWNLOADS