Startseite » Products » Safe Brake Resistors » CUSTOMIZED SAFE BRAKE RESISTORS » Siemens Product Partner » SINAMICS V90 – Brake resistors
The servo inverter Sinamics V90 is intended for use with applications for dynamic motion and processing. The V90 already contains an integrated brake resistor. Nonetheless, some applications require an external brake resistor. KOCH offers safe brake resistors that are ideal for this purpose. They safely dissipate the generative electrical energy and thereby considerably improve the brake and delay capacities.
Rated power
Allocation – Brake resistors for SINAMICS V90
Resistance
Allocation – Brake resistors for SINAMICS V90
Contact
Michael Koch GmbH
Phone: +49 7251 96 26-200
Mail: mail@bremsenergie.de
Voltage | Size | Resistor | max. power [kW] | Rated power [W] | max. Energy [kJ] | KOCH number | resitor | max. Power kW 5% duty cycle*** | nominal power [W] |
1-phase 200VAC – 240VAC | FSA (0.1 – 0.2 kW) | 150 | 1,09 | 20 | 0,8 | BWD250150 | 150 | 1,5 | 100 |
FSB (0.4 kW) | 100 | 1,64 | 21 | 1,23 | BWD250100 | 100 | 1,5 | 100 | |
FSC | 50 | 3,28 | 62 | 2,46 | BWD500050 | 50 | 2,75 | 200 | |
3-phase |
FSD (1kW) | 50 | 3,28 | 62 | 2,46 | BWD500050 | 50 | 2,75 | 200 |
FSD (1.5 – 2kW) | 25 | 6,56 | 123 | 4,92 | BWD600027 | 27 | 4 | 240 | |
3-phase 380VAC – 480VAC |
FSAA | 533 | 1,2 | 30 | 2,4 | BWD250620 | 620 | 1,5 | 100 |
FSA | 160 | 4 | 100 | 8,0 | BWD500160 | 160 | 2,75 | 200 | |
FSB | 70 | 9,1 | 229 | 18,3 | BWD600072 | 72 | 4 | 240 | |
FSC | 27 | 23,7 | 1185 | 189,6 | BWD600100K03LV | 33,3 | 12 | 1200 |
*** at an ambient temperature of 20°C
*Test conditions: Water jet from nozzle 6.3 mm inside diameter,
flow rate 12.5 l / min +/- 5%, water pressure according to volume flow,
distance 2.5- 3m, test duration 3min.
**With fourfold type power and free convection. 1. no short-circuit, 2. no fault to frame, 3. self-extinguishing, 4. no melting of casing. Type power always corresponds to 35% duty cycle of the respective resistor type.
Parameter | Symbol | Value | Unit | Conditions |
---|---|---|---|---|
Tolerance (resistance) | ± 5 | % | Room temperature | |
Temperature coefficient | TK | 20 … 100 | 10-6/K | |
Insulation resistance | Riso | ≥ 100 | MΩ | Umess = 1,000 VDC |
Inductance | L | ≤ 30 | µH | f = 300 kHz, Umess = 50 mV |
Capacity against enclosure | C | ≤ 300 | pF | f = 300 kHz, Umess = 50 mV |
Certifications | cCSAus | Standard CSA-C22.2 and UL508 | ||
cCRus | Standard CSA-C22.2 and UL508 | |||
Maximum permissible operating voltage | UB | ≤ 700 AC | V | Taking into consideration the „intrinsic safety“ |
UB | ≤ 1,000 DC | V | Taking into consideration the „intrinsic safety“ | |
Maximum permissible operating voltage | UB | ≤ 600 AC | V | according to CSA |
UB | ≤ 848 DC | V | according to CSA | |
Isolation voltage | Uiso | ≥ 4,000 AC | V | f = 50 Hz; t = 1 s |
Max. permissible case temp. | ϑc | ≤ 250 | °C | unobstructed convection |
Storage temperature | ϑs | -25 … +85 | °C |
Dimensions and mounting holes (mm)